The LZ-200J is a portable Dual-type Coating Thickness Tester, equipped with both Electromagnetic and Eddy-current testing methods. This unit also has an internal Printer. The LZ-200J can quickly and easily handle coating thickness measurements of various types of coatings on Iron and Steel or non-ferrous substrates. Additionally, the LZ-200J offers many valuable functions, such as calibration, memory, limit setup, and a statistical calculation function, which at the press of a button allows you to find the average value, standard deviation, and largest and smallest values measured.
| Specifications | LZ-200J |
 |
| Measurement Method | Electromagnetic induction / Eddy-current |
 |
| Applications | Non-magnetic coating on iron and steel (ferrous) substrates and Insulating coatings on non-ferrous substrates |
 |
| Measurement Range | Electromagnetic: 0-1500µm or 60.00mils Eddy-current: 0-800µm or 32.00mils |
 |
| Measurement Precision | Electromagnetic: Under 15µm: ±0.3mm, 15µm or greater: ±2% Eddy-current: Under 50µm: ±1µm, 50µm or greater: ±3% |
 |
| Resolution | 0.1µm (less than 100µm), 1.0µm (100µm or greater) |
 |
| Statistical Functions | Number of measurements, Average value, Standard deviation, Maximum value, Minimum value, Block numbers |
 |
| Probe | One-point contact fixed pressure (LEP-J, LHP-J) |
 |
| Display Format | Digital (LCD, smallest displayed unit 0.1mm) |
 |
| Output | RS-232C interface (transmission speed-2400bps) |
 |
| Power Source | AC100V (50/60Hz) or 1.5 ("AA" size Alkaline batteries) x 6 (main unit), Printer ("AA" size Alkaline batteries) x 4 |
 |
| Dimensions & Weight | 120(W) x 250(D) x 55(H)mm, Net 1.0kg, Shipment 2.5kg |
 |
| Accessories | Calibration plate, Iron substrate, Batteries (1.5V, "AA" size Alkaline), Probe adapter, AC adapter, Printer paper, Carrying case |
 |
| Options | Data Management Software "McWave Series" and "MultiProp" (McWave Series and MultiProp are products of CEC Co.) |
 |
Product Manual: Model LE_LH_LZ-200J M- 1177 kB